Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 483
Filtrar
1.
Int. j. odontostomatol. (Print) ; 17(3): 327-334, sept. 2023. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1514371

RESUMO

The mandibular advancements performed in orthognathic surgeries can be stabilized with several techniques when using stable internal fixation. This study aims to comparatively evaluate, in vitro, the mechanical strength in a polyurethane mandibular model for four fixation techniques for sagittal split ramus osteotomy mandibular. 60 samples were divided into 4 groups, with 15 units for each group: group A, group B, group C and group D. Advances of 5 mm were made for each subgroup and fixed with 2.0 mm system plates and monocortical screws in the replicas of human hemimandibles in polyurethane resin. The samples were submitted to mechanical tests of linear loading, being evaluated the peak load and peak deformation. Technique B presented higher peak load (Kgf) and techniques A and B presented higher peak strain (p<0.05). Technique D presented lower peak load and lower peak strain (p<0.05). It is concluded that the study based on the development of new techniques for fixation for sagittal osteotomy of the mandibular ramus is of great importance for the advancement of orthognathic surgery, provided by the technical innovation of more favorable plate models.


Los avances mandibulares realizados en cirugías ortognáticas pueden estabilizarse con varias técnicas cuando se utiliza fijación interna estable. Este estudio tuvo como objetivo evaluar comparativamente, in vitro, la resistencia mecánica en un modelo mandibular de poliuretano para cuatro técnicas de fijación para la osteotomía sagital de la rama mandibular. Se dividieron 60 muestras en 4 grupos, con 15 unidades para cada grupo: grupo A, grupo B, grupo C y grupo D. Se realizaron avances de 5 mm para cada subgrupo y se fijaron con placas de sistema de 2,0 mm y tornillos monocorticales en las réplicas de hemimandíbulas humanas en resina de poliuretano. Las muestras fueron sometidas a pruebas mecánicas de carga lineal, siendo evaluadas la carga máxima y la deformación máxima. La técnica B presentó mayor pico de carga (Kgf) y las técnicas A y B presentaron mayor pico de deformación (p<0,05). La técnica D presentó menor carga máxima y menor tensión máxima (p<0,05). Se concluye que el estudio basado en el desarrollo de nuevas técnicas de fijación para la osteotomía sagital de la rama mandibular es de gran importancia para el avance de la cirugía ortognática, proporcionada por la innovación técnica de modelos de placas más favorables.


Assuntos
Avanço Mandibular/métodos , Osteotomia Sagital do Ramo Mandibular/métodos , Mandíbula/cirurgia , Fenômenos Biomecânicos , Cirurgia Ortognática/métodos , Fixação Interna de Fraturas/métodos
2.
China Journal of Orthopaedics and Traumatology ; (12): 450-453, 2023.
Artigo em Chinês | WPRIM | ID: wpr-986787

RESUMO

OBJECTIVE@#According to the characteristics of spinal burst fractures in high-altitude areas and the local medical conditions, to explore the clinical efficacy of short-segment fixation with pedicle screws combined with screw placement in injured vertebrae in the treatment of thoracolumbar burst fractures.@*METHODS@#From August 2018 to December 2021, 12 patients with single-vertebral thoracolumbar burst fractures without neurological symptoms were treated with injured vertebral screw placement technique, including 7 males and 5 females;aged 29 to 54 years old, with an average of(42.50±7.95) years old;6 cases of traffic accident injury, 4 cases of high fall injury, 2 cases of heavy object injury;2 cases of T11, 4 cases of T12, 3 cases of L1, 2 cases of L2, and 1 case of L3. In the operation, screws were first placed in the upper and lower vertebrae of the fracture, pedicle screws were placed in the injured vertebra, and connecting rods were installed, and the fractured vertebral body was reset by positioning and distraction. Visual analogue scale (VAS) and Japanese Orthopedic Association (JOA) scoring were used to evaluate the changes in pain and quality of life of patients, and the kyphotic correction rate and correction loss rate of the injured segment were measured by X-ray.@*RESULTS@#All operations were successful without significant intraoperative complications. All 12 patients were followed up, the duration ranged from 9 to 27 months, with an mean of (17.75±5.79) months. VAS at 3 days after operation was significantly higher than that at admission (t=6.701, P=0.000). There was significant difference in JOA score between 9 months after operation and at admission (t=5.085, P=0.000). Three days after operation, Cobb angle was (4.42±1.16)°, and the correction rate was (82±5)% compared with (25.67±5.71)° at admission. Cobb angle was (5.08±1.24) °at 9 months after operation, with a corrected loss rate of (16±13)%. No loosening or breakage of internal fixation was found.@*CONCLUSION@#Under the high-altitude hypobaric and hypoxic environment, the effect of the operation should be ensured while reducing the trauma. The application of the technique of placing screws on the injured vertebra can effectively restore and maintain the height of the injured vertebra, with less bleeding and shorter fixed segments, which is an effective method.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Parafusos Pediculares , Altitude , Qualidade de Vida , Vértebras Lombares/lesões , Vértebras Torácicas/lesões , Fraturas da Coluna Vertebral/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas por Compressão , Resultado do Tratamento , Fraturas Cominutivas
3.
China Journal of Orthopaedics and Traumatology ; (12): 268-270, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970860

RESUMO

OBJECTIVE@#To investigate the effect of treatment of Müller A fracture of distal femur with small incision internal fixation assisted by homeopathic bidirectional-traction reduction device.@*METHODS@#From January 2018 to December 2019, 22 patients (14 males and 8 females) with Müller type A distal femoral fractures were treated with homeopathic bidirectional-traction assisted reduction and minimally invasive small incision locking plate internal fixation;The age ranged from 29 to 58 years old with an average of (41.23±7.03) years. The time from injury to operation was 1 to 7 days with an average of (3.41±1.71) days. According to Müller classification, there were 4 cases of type A1, 10 cases of type A2, and 8 cases of type A3. The postoperative knee joint function was evaluated by Schatzker Lambert fracture criterion of distal femur.@*RESULTS@#All the incisions healed in one stage without infection, osteomyelitis and other complications. All the fractures healed without malunion and nonunion. All of 22 patients were followed up for 12 to 18 months with an average of (14.50±2.02) months. The healing time was 3 to 6 months with an average of (4.64±1.14) months. According to Schatzker Lambert criteria for distal femoral fracture, 12 cases were excellent, 6 good, and 4 medium.@*CONCLUSION@#It is an ideal method to treat Müller type A fracture of distal femur with homeopathic bidirectional-traction assisted reduction device and minimally invasive small incision locking plate internal fixation.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Fraturas do Fêmur/cirurgia , Fraturas Femorais Distais , Tração , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Placas Ósseas
4.
China Journal of Orthopaedics and Traumatology ; (12): 255-261, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970858

RESUMO

OBJECTIVE@#To investigate the biomechanical characteristics of different internal fixations for Pauwels type Ⅲ femoral neck fracture with defect, and provide reference for the treatment of femoral neck fracture.@*METHODS@#Three-dimensional (3D) finite element models of femoral neck fractures were established based on CT images, including fracture and fracture with defects. Four internal fixations were simulated, namely, inverted cannulated screw(ICS), ICS combined with medial buttress plate, the femoral neck system (FNS) and FNS combined with medial buttress plate. The von Mises stress, model stiffness and fracture displacements of fracture models under 2 100 N axial loads were measured and compared.@*RESULTS@#When femoral neck fracture was fixed by ICS and FNS, the peak stress was mainly concentrated on the surface of the screw near the fracture line, and the peak stress of FNS is higher than that of ICS;When the medial buttress plate was combined, the peak stress was increased and transferred to medial buttress plate, with more obvious of ICS fixation. For the same fracture model, the stiffness of FNS was higher than that of ICS. Compared with femoral neck fracture with defects, fracture model showed higher stiffness in the same internal fixation. The use of medial buttress plate increased model stiffness, but ICS increased more than FNS. The fracture displacement of ICS model exceeded that of FNS.@*CONCLUSION@#For Pauwels type Ⅲ femoral neck fracture with defects, FNS had better biomechanical properties than ICS. ICS combined with medial buttress plate can better enhance fixation stability and non-locking plate is recommended. FNS had the capability of shear resistance and needn't combine with medial buttress plate.


Assuntos
Humanos , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Placas Ósseas , Fenômenos Biomecânicos , Análise de Elementos Finitos
5.
China Journal of Orthopaedics and Traumatology ; (12): 247-250, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970856

RESUMO

OBJECTIVE@#To investigate the clinical effect of double pulley combined with suture bridge in the treatment of comminuted fracture of the lower pole of the patella.@*METHODS@#From January 2018 to June 2020, 15 patients with comminuted fracture of the lower pole of the patella were treated with double pulley and suture bridge technology, including 9 males and 6 females, aged 28 to 68 years old with an average of (42.4±9.6) years old. All patients had obvious knee joint pain and limited movement after injury. All knee joints were examined by X-ray and CT, which confirmed that they were all comminuted fractures at the lower level of the patella. After operation, X-ray films of the knee joint were taken regularly to understand the fracture healing, the Insall Salvati index was measure, the range of motion of the joint was recorded, and the function of the knee joint was evaluateed by the Bostman scoring system.@*RESULTS@#All the 15 patients were followed up for 7 to 24 months with an average of (11.4±4.2) months, and there was no obvious anterior knee pain. At the last follow-up, the knee joint range of motion of the affected limb was 105° to 140° with an average of (128.5±12.8) °, and the Insall Salvati index was 0.79 to 1.12 with an average of (0.92±0.18). The X-ray film showed that the patella was bone healing, and no anchor fell off, broken, or displaced fracture block was found. Bostman patellar fracture function score was 27.85±2.06, 13 cases were excellent, 2 cases were good.@*CONCLUSION@#Double pulley technique combined with suture bridge technique is reliable for reduction and fixation of comminuted fracture of the lower pole of patella, and patients can start functional exercise early after operation.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Fraturas Cominutivas/cirurgia , Fixação Interna de Fraturas/métodos , Patela/lesões , Fios Ortopédicos , Fraturas Ósseas/cirurgia , Suturas , Resultado do Tratamento
6.
China Journal of Orthopaedics and Traumatology ; (12): 232-235, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970853

RESUMO

OBJECTIVE@#To analyze and compare the clinical efficacy of internal fixation and total hip replacement in the treatment of displaced femoral neck fracture from 55 to 65 years.@*METHODS@#From September 2016 to August 2020, 86 patients with Garden type Ⅲ or Ⅳ femoral neck fracture were divided into two groups according to different surgical methods. Among them, 38 patients were treated with lag screws for internal fixation, there were 26 males and 12 females, aged 55 to 64 years old with an average of(60.2±3.1) years;the other 48 patients were treated with total hip replacement, including 28 males and 20 females, aged from 57 to 65 years old with an average of(61.3±3.8) years. The time from injury to operation ranged from 1 to 3 days. The reoperation rate, incidence of deep infection, Harris score of hip joint function, visual analogue scale(VAS) of pain and patients reported outcome scores(European five-dimensional Health Questionnaire, EQ-5D) were compared between two groups.@*RESULTS@#All patients were followed up for 24 to 54 months with an average of (35.8±10.3) months. There was significant difference in reoperation rate between two groups (P<0.05). There was no significant difference on the incidence of deep infection, hip Harris score and VAS between two groups(P>0.05) . The postoperative EQ-5D score of patients with internal fixation was lower than that of total hip replacement, and the difference was statistically significant(P<0.05).@*CONCLUSION@#Both the surgery of internal fixation and total hip replacement have similar effect in short-and medium term among the patients aged 55 to 65 years old. However, for the reoperation rate, the group of internal fixation was higher than that of total hip replacement. For the subjective functional score of patients, the group of internal fixation was lower than that of total hip replacement.


Assuntos
Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Artroplastia de Quadril/métodos , Resultado do Tratamento , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Reoperação
7.
China Journal of Orthopaedics and Traumatology ; (12): 226-231, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970852

RESUMO

OBJECTIVE@#To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.@*METHODS@#From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.@*RESULTS@#Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).@*CONCLUSION@#Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.


Assuntos
Pessoa de Meia-Idade , Humanos , Resultado do Tratamento , Perda Sanguínea Cirúrgica , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fraturas do Colo Femoral/cirurgia , Parafusos Ósseos
8.
China Journal of Orthopaedics and Traumatology ; (12): 221-225, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970851

RESUMO

OBJECTIVE@#To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.@*METHODS@#The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.@*RESULTS@#The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).@*CONCLUSION@#Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.


Assuntos
Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Robótica , Estudos Retrospectivos , Fraturas do Colo Femoral/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Resultado do Tratamento
9.
China Journal of Orthopaedics and Traumatology ; (12): 216-221, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970850

RESUMO

Femoral head and ipsilateral femoral neck fractures are serious and complicated injuries, which usually yield unsatisfactory results using conventional hip-preserving surgery. The key point of the management and prognosis mainly lies in femoral neck fractures. An apparent and consecutive relationship exists between femoral neck fractures and femoral head fracture-hip dislocation in such injuries. It is believed that disastrous triad of femoral head (DTFH) could summarize these specific injuries, and reflect the injury mechanism and prognostic characteristics. Based on our clinical observation and literature review, DTFH could be divided into three subgroups:TypeⅠ, common DTFH, in which femoral neck fractures occur following femoral head fractures-hip dislocation due to the same trauma; TypeⅡ, iatrogenic DTFH, in which femoral neck fractures come out in the caring process of femoral head fractures-hip dislocation; Type Ⅲ, stressed DTFH, in which femoral neck fractures occur after the management of femoral head fractures-hip dislocation. In the scenario, the line of femoral neck fractures locates distally to the femoral head fractures. Herein, we will discuss clinical characteristics of these types of DTFH.


Assuntos
Humanos , Fraturas do Fêmur/complicações , Fraturas do Colo Femoral/complicações , Cabeça do Fêmur/lesões , Fratura-Luxação , Fixação Interna de Fraturas/métodos , Luxação do Quadril/cirurgia , Prognóstico
10.
China Journal of Orthopaedics and Traumatology ; (12): 203-208, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970848

RESUMO

OBJECTIVE@#To retrospectively analyze efficacy of single structure internal fixation and double structure internal fixation in the treatment of ipsilateral femoral shaft and neck fracture, and analyze their indications.@*METHODS@#From June 2015 to December 2020, 21 patients with ipsilateral femoral shaft and femoral neck fracture were treated, including 14 males and 7 females, aged 23 to 69 years old with an average of(38.1±12.9) years old. According to different femoral shaft fracture sites, some patients were fixed with cephalomedullary implant for both femoral neck and the femoral shaft(single structure, InterTan or PFNA Ⅱ), some patients were fixed with cannulated screws for the femoral neck and a retrograde locking nail for the femoral shaft (dual structure), and postoperative function and complications were recorded during follow-up. In 10 cases of single-structure fixation, the femoral necks were all basicervical fractures, and the femoral shaft fractures were located in the proximal isthmus;11 cases were double-structure fixation, 9 cases in 11 were basal type of femoral neck, 2 cases in 11 were neck type, and the femoral shaft fractures were located in the isthmus and the distal isthmus.@*RESULTS@#All patients were followed up for 12 to 27 months. No femoral head necrosis, deformity, delay or nonunion occurred in the patients with single-structure fixation, and no delayed union or nonunion occurred in femoral shaft fractures;At the final follow-up, Harris score of patients with single-structure fixation was 91.8±4.1, with 8 cases were excellent and 2 cases were good. The fractures of patients with dual-structure fixation achieved good union without femoral head necrosis, except 1 case of femoral shaft fracture had delayed union;At the final follow-up, Harris score of patients with dual-structure fixation was 92.4±5.9, 7 cases were excellent, 3 cases were good, and 1 case was fair.@*CONCLUSION@#Good reduction and fixation is the key to the treatment of such fractures. Both the single-structure fixation and the dual-structure fixation are good methods, and it should be selected according to the locations of femoral shaft and femoral neck fractures. Single-structure fixation is a good choice for femoral shaft fractures located at the proximal isthmus and basal femoral neck fractures. For isthmus and distal femoral shaft fractures combined with ipsilateral femoral neck fractures, dual-structure fixation is recommended.


Assuntos
Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Colo do Fêmur , Estudos Retrospectivos , Fraturas do Colo Femoral/complicações , Fraturas do Fêmur/complicações , Fixação Interna de Fraturas/métodos , Fraturas Femorais Distais , Resultado do Tratamento , Fixação Intramedular de Fraturas/métodos
11.
China Journal of Orthopaedics and Traumatology ; (12): 161-164, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970839

RESUMO

OBJECTIVE@#To investigate the clinical efficacy of needle-guided percutaneous cannulated compression screw fixation in the treatment of acute non-displaced scaphoid fracture of wrist.@*METHODS@#The clinic data of twenty-eight patients with acute non-displaced scaphoid fracture from January 2014 to January 2019 were analyzed retrospectively. According to the intraoperative method of placement of cannulated screw, they were divided into Guide group(16 patients)and Conventional group(12 patients). There were 13 males and 3 females in Guide group, aged from 20 to 60 years old with an average of(31.42±9.71)years old;5 patients were classified as type A2, 3 patients were classified as type B1 and 8 patients were classified as type B2 according to Herbert classification;they were treated with percutaneous cannulated compression screw fixation under the guidance of needle. There were 11 males and 1 female in Conventional group, aged from 23 to 61 years old with an average of(30.51±7.52)years old;5 patients were classified as type A2, 2 patients were classified as type B1 and 5 patients were classified as type B2 according to Herbert classification;they were treated with conventional percutaneous cannulated compression screw fixation. The operation time, screw angle relative to the longitudinal axis of the scaphoid and wrist function score were assessed and compared between the two groups.@*RESULTS@#A total of 28 patients were followed up from 20 to 45 months with an average of (33.00±8.72) months. None of patients had intraoperative complication and incision infection. These patients returned to work gradually 2 weeks after operation, and all fractures healed within 12 weeks. The operation time in the Guide group was significantly less than that in the Conventinal group(P<0.05). Screw angle relative to the longitudinal axis of the scaphoid in the Guide group was significantly smaller than that in the Conventional group(P<0.05). There was no significant difference in Mayo wrist function scores at the last follow-up between the two groups(P>0.05). During the follow-up period, none of the 28 patients showed internal fixation displacement, arthritis, scaphoid necrosis and other complications.@*CONCLUSION@#In the treatment of acute non-displaced scaphoid fractures, the operation time of needle-guided percutaneous cannulated headless compression screw fixation is significantly shorter than that of conventional percutaneous screw fixation, and the screw axis is easier to be parallel to the longitudinal axis of the scaphoid.


Assuntos
Masculino , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Fraturas Ósseas/cirurgia , Osso Escafoide/cirurgia , Punho , Estudos Retrospectivos , Seringas , Traumatismos do Punho/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Resultado do Tratamento
12.
China Journal of Orthopaedics and Traumatology ; (12): 156-160, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970838

RESUMO

OBJECTIVE@#To retrospectively analyze the clinical efficacy of olecranon osteotomy approach in the treatment of Dubberley type Ⅲ coronal fractures of the distal humerus and summarize the treatment experience.@*METHODS@#From January 2016 to June 2020, 17 patients (5 males and 12 females) with Dubberley type Ⅲ coronal fractures of the distal humerus were treated by olecranon osteotomy approach. The age ranged from 37 to78 years old with an average of (58.5±12.9) years old. According to Dubberley classification, there were 5 cases of type Ⅲ A and 12 cases of type Ⅲ B. The curative effect was evaluated using the Borberg-Morrey elbow function score. The flexion, extension and rotation range of motion of the elbow joint, complications and postoperative imaging evaluation were recorded.@*RESULTS@#All the 17 patients got bony union. The follow-up time ranged from 12 to 33 months with an average of (15.6±5.6) months. There was 1 case of ischemic necrosis of capitulum humeri, 2 cases of traumatic arthritis and 1 case of heterotopic ossification, 1 case of malunion of fracture. The range of motion was (114.80±19.50) °. The Broberg-Morrey score was 85.3±8.2, excellent in 5 cases, good in 9 cases, fair in 3 cases and poor in 0 case.@*CONCLUSION@#Through olecranon osteotomy approach, the articular surface of distal humerus could be fully exposed, and the operation is convenient. Anatomical reduction and rigid fixation of the articular surface of distal humerus are the key factors for the succesful outcome.


Assuntos
Masculino , Feminino , Humanos , Adulto , Olécrano/cirurgia , Articulação do Cotovelo/cirurgia , Fraturas do Úmero/cirurgia , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Úmero/cirurgia , Resultado do Tratamento , Amplitude de Movimento Articular
13.
China Journal of Orthopaedics and Traumatology ; (12): 128-132, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970833

RESUMO

OBJECTIVE@#The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.@*METHODS@#From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.@*RESULTS@#All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.@*CONCLUSION@#The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Fraturas do Punho , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Fluoroscopia/métodos , Placas Ósseas , Complicações Pós-Operatórias
14.
Chinese Journal of Traumatology ; (6): 183-186, 2023.
Artigo em Inglês | WPRIM | ID: wpr-981922

RESUMO

For the treatment of an intertrochanteric fracture combined with femoral head necrosis in middle-age patients, it has been controversial whether to perform fracture reduction and fixation first then total hip replacement, or direct total hip replacement. We present a rare case of 53-year-old male patient suffered from bilateral intertrochanteric fracture caused by a road traffic injury. The patient had a history of femoral head necrosis for eight years, and the Harris score was 30. We performed total hip replacement with prolonged biologic shank prostheses for primary repair. One year after the surgery, nearly full range of motion was achieved without instability (active flexion angle of 110°, extension angle of 20°, adduction angle of 40°, abduction angle of 40°, internal rotation angle of 25°, and external rotation angle of 40°). The Harris score was 85. For the middle-aged patient with unstable intertrochanteric fractures and osteonecrosis of the femoral head, we can choose primary repair for concurrent bilateral intertrochanteric fracture and femoral head necrosis with prolonged shank biologic total hip replacement.


Assuntos
Masculino , Pessoa de Meia-Idade , Humanos , Artroplastia de Quadril/métodos , Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Produtos Biológicos , Resultado do Tratamento , Estudos Retrospectivos
15.
China Journal of Orthopaedics and Traumatology ; (12): 676-685, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981755

RESUMO

OBJECTIVE@#To compare the clinical efficacy of screw and bone plate internal fixation in the treatment of Lisfranc injury.@*METHODS@#The databases of Wanfang, CNKI, Pubmed, EMBASE, VIP, BIOSIS and other databases were retrieved by computer, and the clinical trial literature from January 1, 2000 to August 1, 2021 was retrieved, the methodological quality of the included studies was strictly evaluated and the data were extracted, and the obtained data were meta-analyzed by Revman 5.4 software.@*RESULTS@#Nine randomized controlled trial literature and 10 retrospective cohort studies were included, of which 416 patients in the experimental group were treated with screw internal fixation, and 435 patients in the control group were treated with bone plate internal fixation. Meta-analysis showed that the surgical time of the bone plate internal fixation group was longer than that of the screw internal fixation group [MD=-14.40, 95%CI(-17.21, -11.60), P<0.000 01], the postoperative X-ray anatomical reduction of the bone plate internal fixation group [MD=0.47, 95%CI(0.25, 0.86), P=0.01], the excellent and good rate of postoperative American orthopedic foot and ankle society(AOFAS) foot function score[MD=0.25, 95%CI(0.15, 0.42), P<0.000 01], postoperative AOFAS foot function score [MD=-5.51, 95%CI(-10.10, -0.92), P=0.02] of the bone plate fixation group was better than those of the screw internal fixation group. Two kinds of operation method had no statistical different for postoperative fracture healing time[MD=1.91, 95%CI(-1.36, 5.18), P=0.25], postoperative visual analgue scale(VAS)[MD=0.38, 95%CI(0.09, 0.86), P=0.11], postoperative complications [MD=1.32, 95%CI(0.73, 2.40), P=0.36], the postoperative infection [MD=0.84, 95%CI(0.48, 1.46), P=0.53], the postoperative fracture internal fixation loosening [MD=1.25, 95% CI(0.61, 2.53), P=0.54], the postoperative incidence of traumatic arthritis [MD=1.80, 95%CI(0.83, 3.91), P=0.14].@*CONCLUSION@#Bone plate fixation has better short-term and medium-term results and lower reoperation rate in the treatment of Lisfranc injury, so it is recommended to use bone plate fixation in the treatment of Lisfranc injury.


Assuntos
Humanos , Placas Ósseas , Estudos Retrospectivos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Resultado do Tratamento , Complicações Pós-Operatórias
16.
China Journal of Orthopaedics and Traumatology ; (12): 672-675, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981754

RESUMO

OBJECTIVE@#To summarize the surgical treatment of different proximal clavicle fractures, and discuss the classification of proximal clavicle fractures.@*METHODS@#Total of 24 patients with displaced proximal clavicle fractures were treated from January 2017 to December 2020 including 16 males and 8 females, aged 28 to 66 years old. Among them, 20 cases were fresh fractures and 4 cases were old fractures. According to the Edinburgh classification, 14 cases were type 1B1 fractures and 10 cases were type 1B2 fractures. The different internal fixation methods were selected for internal fixation treatment according to different fracture types.The operation time, blood loss, preoperative and postoperative displacement difference, fracture healing time and Rockwood scoring system were recorded.@*RESULTS@#All patients were followed up for 12 to 24 months. There were no patients with infection or loss of reduction after the operation. Three patients had internal fixation failure after operation, and the internal fixation device was removed. Results The operation time was 30 to 65 min, and the blood loss was 15 to 40 ml. No important nerves, blood vessels, or organs were damaged. The imaging healing time was 3 to 6 months. According to the Rockwood functional score, the total score was (13.50±1.86), pain (2.57±0.50), range of motion (2.78±0.41), muscle strength (2.93±0.28), restricted daily activity (2.85±0.35), subjective results (2.63±0.61);the results were excellent in 20 cases, good in 3 cases, fair in 1 case.@*CONCLUSION@#Proximal clavicular fracture is a type of fracture with low incidence. According to different fracture types, different internal fixation methods and treatment methods can be selected, and satisfactory surgical results can be achieved.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Clavícula/cirurgia , Resultado do Tratamento , Placas Ósseas , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
17.
China Journal of Orthopaedics and Traumatology ; (12): 619-622, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981744

RESUMO

OBJECTIVE@#To explore the clinical effect of Kirschner wire intramedullary fixation in the treatment of both-bone forearm fractures in children of high altitude area.@*METHODS@#From August 2020 to December 2021, 19 children were treated with Kirschner wire intramedullary fixation including 11 males and 8 females, aged from 4 to 13 years old with an average of (8.16±2.71) years old. The course of disease was 1 to 10 days, with a mean of (4.11±2.51) d. First, close reduction was performed. If the reduction was unsuccessful, limited open reduction was performed, followed by Kirschner wire intramedullary fixation of the radius and ulna. The fracture healing was evaluated by X-ray after operation, and the curative effect was evaluated by Anderson forearm function score standard.@*RESULTS@#The wound healed well after operation, 2 cases had clinical manifestations of needle tail irritation after operation, and the symptoms disappeared after removing the internal fixation. The average follow-up time was(7.68±3.50) months (3 to 14 months). X-ray showed that all fracture healing in follow-up, Anderson forearm function score showed excellent in 16 cases, good in 2 cases and fair in 1 case at the final follow-up.@*CONCLUSION@#Children with fractures in plateau areas often have delayed medical treatment, lack of medical conditions and insufficient compliance. Based on these characteristics, Kirschner wire intramedullary fixation for the treatment of children's double forearm fractures has the advantages of small injury and rapid recovery. It is a kind of operation method that can be popularized.


Assuntos
Masculino , Feminino , Humanos , Criança , Pré-Escolar , Adolescente , Fios Ortopédicos , Antebraço , Altitude , Resultado do Tratamento , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas do Rádio/cirurgia , Fixação Intramedular de Fraturas/métodos
18.
China Journal of Orthopaedics and Traumatology ; (12): 574-578, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981735

RESUMO

OBJECTIVE@#To analyze the clinical outcomes of mini-plate combined with wireforms in the treatment of Type C distal radial fractures with marginal articular fragments.@*METHODS@#This retrospective study included a total of 10 cases, including 5 males and 5 females, with 6 cases involving the left side and 4 cases involving the right side, of Type C distal radial fractures with marginal articular fragments. The age of the patients ranged from 35 to 67 years old. All patients underwent surgical treatment utilizing mini-plate combined with wireforms for internal fixation.@*RESULTS@#The follow-up period ranged from 6 to 18 months. Complete fracture healing was observed in all cases, with healing times ranging from 10 to 16 weeks. During the entire follow-up period, patients reported high levels of satisfaction with the treatment outcomes, and there were no incidences of incision infection, chronic wrist pain, or wrist traumatic arthritis. At the final follow-up assessment, the Mayo score for the wrist joint ranged from 85 to 95, with 7 cases rated as excellent and 3 cases as good.@*CONCLUSION@#Mini-plate combined with wireforms proves to be an effective fixation method for Type C distal radial fractures with marginal articular fragments. The early initiation of wrist joint exercises, strong fixation, maintenance of proper reduction, minimal complications, and high rates of excellent and good outcomes demonstrate the reliability and efficacy of this treatment approach.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Reprodutibilidade dos Testes , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Fraturas do Punho , Articulação do Punho , Placas Ósseas , Amplitude de Movimento Articular
19.
China Journal of Orthopaedics and Traumatology ; (12): 570-573, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981734

RESUMO

OBJECTIVE@#To develop a reduction device for the arthroscopy-assisted treatment of tibial plateau fracture and explore its clinical efficacy.@*METHODS@#From May 2018 to September 2019, 21 patients with tibial plateau fracture were treated, including 17 males and 4 females. Their ages ranged from 18 to 55 years old with an average of (38.6±8.7) years old. There were 5 cases of Schatzker typeⅡand 16 cases of Schatzker type Ⅲ. The self-designed reductor combined with arthroscope was used for auxiliary reduction and fixation(minimally invasive percutaneous plate osteosynthesis). The efficacy was analyzed by observing the operation time, blood loss, fracture healing time and knee function(HSS and IKDC scoring criteria).@*RESULTS@#All the 21 patients were followed up for 8 to 24 with an average of(14.0±3.1) months. The operative time ranged from 70 to 95 min with an average of(81.7±7.6)min, incision length ranged from 4 to 7 cm with an average of(5.3±0.9) cm, intraoperative blood loss ranged from 20 to 50 ml with an average of(35.3±5.2) ml, postoperative weight-bearing time ranged from 30 to 50 d with an average of(35.1±9.2) d, fracture healing time ranged from 65 to 90 d with an average of(75.0±4.4) d, and complications were 0 cases, respectively. The fracture was well healed and no screw plate fracture was observed. The knee function scores of HSS and IKDC 18 months after operation were significantly higher than those before operation(P<0.05).@*CONCLUSION@#The custom-made reduction tool for the arthroscopic management of tibial plateau fracture is reasonable in design and simple in operation. The specific reduction tool could effectively reduce the fracture, and shorten the fixation time with minimally invasive procedure.


Assuntos
Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Fraturas do Planalto Tibial , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Placas Ósseas , Estudos Retrospectivos
20.
China Journal of Orthopaedics and Traumatology ; (12): 532-542, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981728

RESUMO

OBJECTIVE@#To analyze the clinical characteristics of intervertebral disc tissue injury and herniation into the vertebral body in thoracolumbar fracture on fracture healing, vertebral bone defect volume and intervertebral space height.@*METHODS@#From April 2016 to April 2020, a total of 140 patients with thoracolumbar single vertebral fracture combined with upper intervertebral disc injury treated with pedicle screw rod system reduction and internal fixation in our hospital. There were 83 males and 57 females, aged from 19 to 58 years old, with an average age of (39.33±10.26) years old. All patients were followed up regularly 6 months, 12 months and 18 months after surgery. The patients with injured intervertebral disc tissue not herniated into the fractured vertebral body were the control group, and the patients with injured intervertebral disc and herniated into the fractured vertebral body were the observation group. By detecting the thoracolumbar AP and lateral X-ray films, CT and MRI of the thoracolumbar segment at different follow-up time, calculate the changes of the wedge angle of the fractured vertebral body, the sagittal kyphosis angle and the height of the superior adjacent intervertebral space, the changes of the fracture healing and bone defect volume after the reduction of the vertebral body, and the changes of the intervertebral disc degeneration grade. The prognosis was evaluated by visual analogue scale(VAS) and Oswestry disability index(ODI). Finally, the differences of the above results among different groups were comprehensively analyzed.@*RESULTS@#All the patients had normal wound healing without complications. A total of 87 patients received complete follow-up data, at least 18 months after internal fixation. Thoracolumbar AP and lateral X-ray films showed that 18 months after the reduction and internal fixation operation, the vertebral wedge angle, sagittal kyphosis angle and the height of the upper adjacent intervertebral space in the observation group were greater than those in the control group(P<0.05). CT scanning showed that the deformity of the fracture healed 12 months after the vertebral body reduction in the observation group and formed a "cavity" of bone defect connected with the intervertebral space, and its volume was significantly increased compared with that before (P<0.05). MRI scanning showed that the degeneration rate of injured intervertebral discs in the observation group was more serious than that in the control group 12 months after operation(P<0.05). However, there was no significant difference in VAS and ODI score at each time.@*CONCLUSION@#Herniation of injured intervertebral disc tissue hernias into the fractured vertebral body leads to increased bone resorption defect volume around the fracture and forms a malunion "cavity" connected with the intervertebral space. This may be the main reason for the change of vertebral wedge angle, the increase of sagittal kyphosis angle and the decrease of intervertebral space height after removal of internal fixation devices.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Corpo Vertebral/lesões , Vértebras Lombares/lesões , Vértebras Torácicas/lesões , Resultado do Tratamento , Fraturas Ósseas , Fraturas da Coluna Vertebral/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Pediculares , Cifose/cirurgia , Disco Intervertebral/cirurgia , Hérnia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA